SUBARU impreza SERVICE and USER MANUAL

High Voltage Battery Cooling System

Sort by: default name
High Voltage Battery Cooling System INSPECTION High Voltage Battery Cooling System INSPECTION HYBRID ELECTRIC VEHICLE > High Voltage Battery Cooling System INSPECTION 1. DUCT Check the duct for clogging, crack, or deformation. If defective, replace the duct. 2. FAN MOTOR UNIT INSPECTION 1. Check the...
High Voltage Battery Cooling System INSTALLATION High Voltage Battery Cooling System INSTALLATION HYBRID ELECTRIC VEHICLE > High Voltage Battery Cooling System INSTALLATION 1. COOLING DUCT FRONT (FRONT) Install each part in the reverse order of removal. Tightening torque: 33 N·m (3.4 kgf-m, 24.3 ft-lb)...
High Voltage Battery Cooling System REMOVAL High Voltage Battery Cooling System REMOVAL HYBRID ELECTRIC VEHICLE > High Voltage Battery Cooling System REMOVAL 1. COOLING DUCT FRONT (FRONT) 1. Disconnect the ground cable from battery. NOTE NOTE: For the 12 volt engine restart battery, disconnect the...